Home /  Products & Solutions /  SOLIVIA Central Inverters /  SOLIVIA CL 250  

SOLIVIA CL 250

SOLIVIA CL 250

The brand new utility-scale SOLIVIA central inverters have a high efficiency of 98.0 %. The easily accessible components in the central inverter cabinet make maintenance very easy. If a fault should occur, the diagnostic function will help you identify the affected module quickly and allow a rapid replacement.

The SOLIVIA central inverters are based on technologically sophisticated drive technology and make them a perfect match for utility-scale PV plants. The central inverter is compatible with all types of solar modules.

Delta’s SOLIVIA CL 250 is particularly suitable for users who are looking for central inverters for largescale to utility-scale PV plants.

 

Features:

  • Maximum efficiency of 98.0%
  • Based on technologically sophisticated drive technology
  • Compatible with all types of solar modules
  • State-of-the-art touch-screen display
  • Easy maintenance
  • Flexible system design to 1 MW
  • Advanced utility capabilities
  • User configurable interfaces

 

 Input (DC)  Output (AC)  
 Max. recommended 
 PV power (kWP)
 275  Nominal power (kW)  250
 Maximum voltage (V)      850  Max. power k(W)*****  250
 Full power MPP range (V)  450 - 850  Nominal voltage (V)  3 phase 290
 Max. current (A)  573  Nominal frequency (Hz)  50 / 60
     Power factor (cos φ)  ≥ 0.99 @ nominal power***
     Total harmonic distortion (THD  < 3 % @ nominal power
 General specification  Mechanical design  
 Model name  SOLIVIA CL 250 AP G1 MS
 (master)
 SOLIVIA CL 250 AP G1 SL
 (slave)****
 Size  (L x W x D )  1800 x 1000 x 800 mm
 Delta part number  EOE98030414 (master)
 EOE98030415 (slave)****
 Weight (kg)  600
 Max. efficiency (%)  > 98.0 % **  Cooling    Liquid cooling (closed loop system) / air cooling (1100 m3/h)
 Efficiency EU > 97.5 % **  AC connectors  Terminal clamps
 Operating temperature  -10 ... +40 °C  DC connectors  Cable ring lugs
 Storage temperature  -25 ... +70 °C  Communication   Ethernet, Internal PLC with
 data logger, GPRS Modem
 (optional)
 Humidity (%)  15 ... 85 % RH   Display 15” Touch screen
 Max. operating altitude (m)  2000 (above sea level)
 Standards  Directives  
 Protection degree  IP00 *  EMC  EN61000-6-2; EN61000-6-4
 Safety class  I    
 Configurable trip parameters  Yes    
Insulation monitoring  Yes    
 Anti-islanding protection  Yes    
 Safety EN50178; EN60439-1; EN50274

* IP00 with collar for exhaust air system. Depending on the connection of the exhaust air system to the collar, a higher protection class is achieved

**  Efficiency measured without transformer

*** Default; adjustable (-0.85 lagging to +0.85 leading)

**** The CL 250 slave inverter lacks the HMI and PLC controller. The CL 250 master shows the operating status of the complete system. A system consists of 1 master and up to 3 slaves.

***** The maximum AC power value indicates the power an inverter might be able to deliver.  However, such a maximum AC power may not necessarily be achieved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title Type Size Date
Catalogue SOLIVIA Australia en.pdf PDF 2,14 MB 2012-08-27

Title Type Size Date

© 2010 Delta Energy Systems (Germany) GmbH, All Rights Reserved