Overview

Perfect for Tough Challenges

The combination of transformer-based technology and protection degree IP65 allows the inverter to be used in harsh enviroments, e.g. in locations near saltwater. When PV modules are used that need to be grounded, this inverter is the ideal choice. It not only supports negative and positive grounding, but also offers several monitoring methods.
The inverter can be used with input voltages up to 600 V and operating temperatures up to 70 °C. Gradual derating does not start before 55 °C.

Extended functionality

The inverter offers an extended MPP tracking function to improve the yield. For some countries powerful functions for controlling active and reactive power are available.
The comprehensive statistics as well as all messages about the current operating status and the complete life-time operating behavior can be read out on the easy-to-use display.
When the inverter is connected to a monitoring system - e.g. the Delta SOLIVIA Monitor 2.0, it can be supervised online.

Easy Installation

The simple on-display commissioning procedure guides the installer through all settings necessary to set up the inverter correctly. When an installation consists of multiple inverters of the same type, the settings of one inverter can be easily copied to the other inverters via the USB interface.
The inverter contains an integrated DC disconnector. A mounting plate and IP65 AC plug are included in the scope of delivery.

Technical Data

Input (DC)
SOLIVIA 5.0 TR
Max. recommended PV power 6000 WP (5320 WP DE / 5250 WP BE)
Nominal power 5500 W (4850 W DE / BE)
Voltage range 125 ... 600 V
Full power MPP range 150 ... 480 V
Nominal current 15.7 A @ 360 V
Max. current 36.6 A
Output (AC)
SOLIVIA 5.0 TR
Nominal apparent power 5000 VA 1), 2), 3)
Voltage range 184 ... 264 V 4)
Nominal current 22 A
Nominal frequency 50 Hz
Frequency range 45 ... 65 Hz 4)
Power factor adjustable 0.8 cap ... 0.8 ind
Total harmonic distortion (THD) < 5 % @ nominal apparent power
General Specification
SOLIVIA 5.0 TR
Model name SOLIVIA 5.0 EU G4 TR
Part number Delta EOE46010253
Max. efficiency 96.1 %
Efficiency EU 94.8 %
Operating temperature -25 ... +70 °C
Full power without derating -25 ... +55 °C
Storage temperature -25 ... +80 °C
Humidity 0 ... 95 %
Max. operating altitude 2000 m (above sea level)
Dimensions / connections
SOLIVIA 5.0 TR
Size (H x W x D) 512 x 410 x 182 mm
Weight 31.0 kg
Cooling Convection
AC connector Wieland RST25i3S
DC connector 2 pairs of Multi-Contact MC4
Communication interfaces 2 x RS485 (RJ45) + 1 USB A 2.0
DC disconnector Integrated
Display 3 LEDs, 4-line LCD
Safety / Standards
SOLIVIA 5.0 TR
Protection degree IP65
Safety class I
Configurable trip parameters Yes
Insulation monitoring Yes
Overload behavior Current limitation; power limitation
Anti-islanding protection / Grid regulation VDE 0126-1-1/A1; UTE C15-712-1; France/Islands (60 Hz); RD 661/2007; RD 1699/2011; CEI0-21; Synergrid C10/11 (06/2012); EN 50438; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014
EMC EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
Safety IEC62109-1 / -2

1) Cos Phi = 1 (VA = W)

2) Continuous nominal active power in the range of Cos Phi = 0.95 cap ... 0.95 ind

3) AC power can be limited at the inverter during commissioning to meet country-specific regulations regarding the maximum permissible grid load.