Overview

Maximum profitability

The RPI H3 solar inverter features a 3 kVA power output. This new single phase transformerless solar inverter is designed for residential PV applications where maximum versatility and profitability are important. Thanks to the high maximum efficiency up to 97 %, optimum yield from the PV plant is ensured from the device.

Flexible system design

For the system planner, maximum flexibility is ensured thanks to a wide input voltage range of 125 - 600 V. The new unit is compatible with major types of PV modules and the robust IP65 rated enclosure allows outdoor installation.

Simple installation

The lightweight and compact design of the RPI H3 greatly simplifies installation. The inverter includes a unique wall bracket in the scope of delivery.

Technical Data

Input (DC)
RPI H3
Max. recommended PV power 3.78 kWp 
Nominal power 3.15 kW 
Voltage range 125 ... 600 V 1) 
Full power MPP range 125 ... 500 V 
Max. current 10 A 
Max. number of MPP trackers
Output (AC)
RPI H3
Nominal apparent power 3 kVA 2)
Voltage range 230 -20%/+22%, 1 Phase (L, N, PE or L, L, PE) 3) 
Nominal current 13 A
Nominal frequency 50 / 60 Hz
Frequency range 50 / 60 Hz +- 5 Hz 3) 
Power factor adjustable 0.8 cap ... 0.8 ind 
Total harmonic distortion (THD) <3 % @ nominal apparent power
General Specification
RPI H3
Model name RPI H3_110 
Part number Delta RPI302N63E0000 
Max. efficiency 97.0 % 
Efficiency EU 96.2 % 
Operating temperature -25 ... +60 degrees C 
Full power without derating -25 ... +40 degrees C 
Storage temperature -25 ... +60 degrees C 
Humidity 0 ... 95 % non-condensing 
Max. operating altitude 2000 m (above sea level)
Dimensions / connections
RPI H3
Size (H x W x D) 367 x 420 x 157 mm 
Weight 15 kg
Cooling Natural convection
AC connector Wieland RST25i3S B1G M01
DC connector 2 pairs of Multi-Contact MC4
Communication interfaces 2 x RS485, 1 x dry contact, 4 x digital inputs
DC disconnector Integrated 
Display 2 LEDs, 2-line LCD
Safety / Standards
RPI H3
Protection degree IP65 
Safety class
Configurable trip parameters Yes 
Insulation monitoring Yes 
Overload behavior Current limitation; power limitation
Anti-islanding protection / Grid regulation VDE 0126-1-1; VDE-AR-N 4105; C10/C11
2012 / VDE 126 A1; VFR 2013 / 2014; VDE 16 1-1 A1;
UTE 15-712; French Islands 50 Hz; UK G83-2
EMC EN61000-6-2; EN61000-6-3
Safety IEC62109-1 / -2; CE compliance

1) No risk of electrical damage til 630 V

2) Cos Phi = 1 (VA = W)

3) AC voltage and frequency range will be programmed according to the individual country requirements.